곧 출시
Omada 6-Port 10/100Mbps Unmanaged Desktop Switch with 4-Port PoE+
- 6× 10/100 Mbps RJ45 ports
- 4× PoE+ Ports, transfer data and power on one single cable
- Works with IEEE 802.3af/at compliant PDs
- Supports PoE Power up to 30 W for each PoE port
- Supports PoE Power up to 67 W for all PoE ports*
- Up to 250m (820ft) data and power transmitting range under Extend Mode**
- Priority Mode ensures high priority of ports 1–2 to guarantee the quality of sensitive application
- PoE Auto Recovery guarantees stable operation of PoE devices by automatically rebooting the dropped or unresponsive PD devices
- Plug and Play. No configuration or central management required.†


| 하드웨어 사양 | |
|---|---|
| 인터페이스 및 주요 사양 | • 6× 10/100 Mbps RJ45 Ports (ports 1–4 support 802.3af/at PoE+)• AUTO Negotiation• AUTO MDI/MDIX |
| 네트워크 미디어 | • 10BASE-T: UTP category 3, 4, 5 cable (maximum 100m)• EIA/TIA-568 100Ω STP (maximum 100m)• 100BASE-TX: UTP category 5, 5e cable (maximum 100m)• EIA/TIA-568 100Ω STP (maximum 100m) |
| 팬(Fan) 수량 | Fanless |
| 물리적 보안 잠금 장치 | Yes |
| 외부 전원 공급 | External Power Adapter (Output: 53.5 V DC / 1.31 A) |
| 패킷 전달 속도 | 0.8928 Mpps |
| PoE 포트 (RJ45) | • Standard: 802.3 af/at compliant• PoE Ports: Ports 1–4• Power Supply: 67 W |
| MAC 주소 테이블 | 2K |
| 점보 프레임 | 2 KB |
| 스위칭 용량 | 1.2 Gbps |
| 크기 ( 가로 x 세로 x 높이 ) | 6.2 × 4.0 × 1.0 in (158 × 101 × 25 mm) |
| 최대 전력 소모량 | • 2.52 W (220 V / 50 Hz, no PD connected)• 75.4 W (220 V / 50 Hz, with 67 W PD connected) |
| 최대 방열수치 | • 8.59 BTU/h(no PD connected)• 257.11 BTU/h(with 67 W PD connected) |
| 소프트웨어 기능 | |
|---|---|
| 고급 기능 | • Compatible With IEEE 802.3af/at Compliant PDs• Extend Mode: Ports 1–4• Priority Mode: Ports 1–2• PoE Auto Recovery: Ports 1-4• Mac Address Auto-Learning and Auto-Aging• IEEE802.3x Flow Control For Full-Duplex Mode and Backpressure for Half-Duplex Mode |
| 전송 방법 | Store-And-Forward |
| 기타 | |
|---|---|
| 인증 | FCC, CE, RoHS |
| 구성품 | • DS106P• Power Adapter• Installation Guide |
| 환경 | • Operating Temperature: 0–40 ℃ (32–104 ℉)• Storage Temperature: -40–70 ℃ (-40–158 ℉)• Operating Humidity: 10–90% RH non-condensing• Storage Humidity: 5–90% RH non-condensing |
*PoE budget calculations are based on laboratory testing. Actual PoE power budget is not guaranteed and will vary as a result of client limitations and environmental factors.
**The speed of the ports in extend mode will downgrade to 10 Mbps. The actual transmission distance may vary due to power consumption of PoE-powered devices or the cable quality and type.
△Numbers after different modes represent the effective ports for that mode.
†Omada Unmanaged Switches do not support Omada SDN central management.